FISHING OXYGENATION SYSTEMS
 
KeepAlive Aerators, Bait Tanks & Fishing Oxygen Systems

E-Mail
KeepAlive Aerators and Bait Tanks keep tournament fish and bait alive and healthy with either pure oxygen systems or aeration.
E-Mail
Tel. 727-841-0407 P.O. Box 1952, Tarpon Springs, FL 34688 Fax 727-815-8049

 

Home Index Portable Units Re-circulating Kits Thru-Hull Units Conversion Kits
Tanks Oxygen Systems Accessories Installation Guide To Aeration Technical Manual
Videos Places To Purchase Professionals Contest Awards Links
 

KeepAlive® Pure Oxygen Infusor® Systems

Best Quality at Affordable Prices!

These regulators are made of nickel plated brass . Absolutely no aluminum! Don't be fooled by inexpensive aluminum regulators that are easily affected by corrosion.

The Best Regulator Warranty Available.

ALWAYS FOLLOW GOOD SAFETY PRACTICES WHEN USING OXYGEN!

BE SURE TO VISIT OUR NEW OXYGEN SITE AT wwwfisho2go.com

Pure Oxygen and Carbon Dioxide Build-up

When using pure oxygen, remember that the carbon dioxide given off by fish will not dissipate unless some form of aeration occurs within the tank. As carbon dioxide builds up in the water, fish lose the ability to absorb oxygen and dissipate carbon dioxide, and may suffocate.

REGULATORS

KeepAlive® O2GO
OXYGEN REGULATOR


Click on Photo to Enlarge

KA902-O2
Designed for use in a marine environment.
Warning: Not for medical use.

Practice Catch & Release!

6 MONTH WARRANTY AGAINST DEFECTS & WORKMANSHIP,
PLUS

LIMITED-LIFETIME
REPLACEMENT WARRANTY

KA902-O2 Regulator 
Introductory Price $179.95
Weight: 1.63 lbs

 
The KeepAlive O2GO is the answer for a quality oxygen regulator with a price for all anglers. Rugged body components of brass, and nickel plated brass to withstand the rigors and harshness of the marine environment.

11 Settings: OFF, 1/32, 1/16, ⅛, 1/4, ½, ¾, 1, 1½, 2, and 4 liters per minute. These settings will allow various oxygen ratios with inexpensive air stones. The KA902-O2 also provides sufficient pressure and oxygen for premium quality diffusers as our KA970-O2,  KA975 and KA9100 diffuser. At it's largest setting, the KA970 and KA975 will consume 3/4 liters per minute.

Nickel Plated Brass  with special internal components. Designed for use in a marine environment.

Nut and Nipple style regulator body for use with CGA 540 Inlet Valve Cylinders.

Oxygen tank pressure gauge with gauge protector. Barbed Outlet for direct attachment of oxygen tubing.

Designed for use in a marine environment.
Warning: Not for medical use.

   


Click on photo to enlarge

Designed for use in a marine environment.
Warning: Not for medical use.

Practice Catch & Release!

6 MONTH WARRANTY AGAINST DEFECTS & WORKMANSHIP,
PLUS

LIMITED-LIFETIME
REPLACEMENT WARRANTY

KA901 Regulator $299.95
Weight: 1.61 lbs

The FISH-FLO2 is designed for use in a harsh marine environment! With technical assistance from  Mr. Gene Gilliland of the Oklahoma Fishery Research Lab and KeepAlive, Inc.,  and manufacturing expertise by FISH-FLO2, the FISH-FLO2 Marine Regulator was born.

Nickel Plated Brass  with special internal components. Designed for use in a marine environment.

11 Settings: OFF, 1/32, 1/16, , 1/4, ½, ¾, 1, 2, 4, 6, and 8 liters per minute. These settings will allow various oxygen ratios with inexpensive air stones. The KA901 also provides sufficient pressure and oxygen  for  premium  quality  diffusers  as  our
KA970-O2, KA975 and KA9100 diffuser. At it's largest setting, the KA970-O2 and KA975 will consume 3/4 liters per minute.

Nut and Nipple style regulator body for use with CGA 540 Inlet Valve Cylinders.

Oxygen tank pressure gauge with gauge protector. Barbed Outlet for direct attachment of oxygen tubing.

Designed for use in a marine environment.
Warning: Not for medical use.

OXYGEN CYLINDERS

KA924 - KA915 - KA911


Click on photo to enlarge

 

 


TYPICAL COMPLETE SYSTEM
KA902-O2 Regulator (Coming Soon)
KA970 Diffuser
KA915 Cylinder

CYLINDERS ONLY

KA911 Cylinder $109.95
KA915 Cylinder
$119.95
KA924 Cylinder $129.95

KeepAlive® Pure Oxygen Infusor® Systems  use  Brass CGA 540 Inlet Cylinder Valves. Cylinders can be refilled from inexpensive commercial welding oxygen sources.
 

FLOW RATE

KA911 KA915 KA924
1/32 LPM 136 hours 226 hours 362 hours
1/16 LPM 68 hours 113 hours 181 hours

CYLINDER DIMENSIONS (Not including valve)
KA915 11" Tall, 4.38" Diameter, 255 liters.
KA915 15" Tall, 4.38" Diameter, 425 liters.
KA924 24" Tall, 4.38" Diameter, 680 liters.

Cylinders have a white coat of baked on bonded powder paint.

RECOMMENDED PROCEDURE FOR VALVING OXYGEN CYLINDERS

Warning: Not for medical use!

Use industrial oxygen available from local welding shops.


TYPICAL COMPLETE SYSTEM

KA901 Regulator
KA975 Diffuser
KA915 Cylinder

Part

No.

Service

Pressure

Diameter

Length

Empty

Weight

Oxygen

Water

Thread

Size 

 

(psi / bar)

(in / mm)

(in / mm)

(lbs / kgs)

(cu ft / liters)

(lbs / liters)

 

KA924

2015 / 139

4.38 / 111.3

24.9 / 632

7.4 / 3.4

24.0 / 680

10.2 / 4.6

.750-16UNF-2B

KA915

2015 / 139

4.38 / 111.3

16.5 / 419

5.1 / 2.3

15.0 / 425

6.4 / 2.9

.750-16UNF-2B

KA911

2015 / 139

4.38 / 111.3

10.7 / 272

3.6 / 1.6

9.0 / 255

3.8 / 1.7

.750-16UNF-2B

DIFFUSER DELIVERY SYSTEM

KA970 DIKA97O DIFFUSERFFUSER

QUALITY AND ECONOMICALLY PRICED!

KA970 Diffuser $49.95

Features and Benefits

  • The KA970 is one of the most efficient diffusers on the market. It uses less gas and requires fewer diffusers to achieve the same results.

  • Strong construction. The ceramic plate is set in a stainless steel frame and a stainless steel hose barb.

  • Easy to install and simple to operate. It requires no power or complex attachment procedures.

  • Warranty - 2 years covering defective materials and workmanship.

Diffusing Area: 3"  Diameter (7.6 cm)
Overall Size: 3.4" Diameter (8.6 cm)

KA975 DIFFUSER

One of the simplest ways to dissolve oxygen in water is to introduce the oxygen as small bubbles. The smaller the bubbles the more efficient the absorption of oxygen.


KA975 Diffuser

The KA975 microbubble oxygen diffuser produces a cloud of extremely fine bubbles - 100 to 500 microns. This is much finer than graphite or carborundum diffusers, or porous hose, and because the diffuser is flat, the bubbles do not coalesce as with circular section diffusers.

The KA975 diffuser uses an ultra fine pore ceramic plate which ensures uniform bubbles across its entire surface. The ceramic is a clean and inert material.

The KA975 diffuser requires a regulator with a minimum of 25-35 lbs of output pressure.

KA975 Diffuser $79.95
KA9100 Diffuser $99.95

KeepAlive Diffusers  are the finest quality in the industry, and are manufactured for KeepAlive. A quality diffuser is extremely important. Any lesser quality diffuser will produce larger bubbles and consume more oxygen.

Features and Benefits

  • The KA975 and KA9100 are the most efficient diffusers on the market. They use less gas and requires fewer diffusers to achieve the same results.

  • Robust construction. The ceramic plate is set in a rigid enamel coated aluminum frame and will not break if frozen.

  • Easy to install and simple to operate. It requires no power or complex attachment procedures.

  • Warranty - 2 years covering defective materials and workmanship.

Bubbling pressure

25 to 35 psi. (1.7 to 2.4 bar)

Absorption efficiency

Largely depends on submerged depth (or operating pressure), typically 40% to 50% at 1m depth; can be as high as 80% or even 100% at depths of 6m or more (also depends on flow rate).
Model KA975 KA9100
Diffusing area 6" x 1 1/8"
(15cm x 3cm)
12 1/8" x 1 1/8"
(31cm x 3cm)
Overall size 8 1/2" x 1 3/4"
(22cm x 4.5cm)
14 1/2" x 1 3/4"
(37cm x 4.5cm)
Weight 0.6lbs
(310g)
1.2lbs
(535g)
Recommended
operating range
up to 0.75 LPM
(1.6 SCFH)
up to 1.55 LPM
(3.2 SCFH)
Maximum flow rate
 @ 50 psi (3.5 bar)
2.2 LPM
(4.7 SCFH)
4.5 LPM
(9.5 SCFH)
Gas inlet connection 3/16" Hose Barb. 1/4" Hose Barb.

A DIFFUSER IS YOUR DELIVERY SYSTEM. DON'T SKIMP. BUY THE BEST!

FLEXIBLE TRANS-FILLS

Trans-fills with safety features cannot be stressed enough.
Keep
SAFETY  first when filling your own cylinders!
KeepAlive Transfills are the SAFEST trans-fills available for anglers.

NOT RECOMMENDED

A rigid trans-fill has inherent deficiencies and should not be used!

  • Filling a cylinder with a rigid trans-fill can be hazardous! Stress due to the weight of a cylinder on the trans-fill and associated connections may separate and result in serious injuries.

  • Most rigid trans-fills do not have a slow filling orifice, Cylinders can overheat to dangerous levels and cylinders may be damaged.

KA950 FLEXIBLE TRANS-FILL

TRANSFILL SAFETY INSTRUCTIONS

KA950 FLEXIBLE TRANS-FILL
Introductory Special:
KA950 $299.95

Safety Features  

  • Flexible high pressure hose. Cylinder can be  placed on a solid surface while filling.

  • A slow filling orifice to prevent overheating of cylinders and hazardous conditions.

  • Single gauge will monitor filling cylinder pressure with filling cylinder valve open.

  • Single gauge will monitor supply cylinder pressure with filling cylinder valve closed.

  • Bleed valve to remove 2000 lbs of pressure from trans-fill before loosening and removing connections.

SAFETY FIRST AND ALWAYS!

 

NOT RECOMMENDED

A rigid trans-fill has inherent deficiencies and should not be used!

  • Filling a cylinder with a rigid trans-fill can be hazardous! Stress due to the weight of a cylinder on the trans-fill and associated connections may separate and result in serious injuries.

  • Most rigid trans-fills do not have a slow filling orifice, Cylinders can overheat to dangerous levels and cylinders may be damaged.

 

KeepAlive Aerators and Livewells
will keep your fish alive and healthy!

Legal Terms of Use