Sistemas de Oxígeno Puro  

KeepAlive Aireadores y Viveros
mantendrá a sus peces vivos y saludables!

  KeepAlive Aireadores y Tanques para Carnada  

E-Mail


E-Mail
Tel. 727-841-0407 P.O. Box 1952, Tarpon Springs, FL 34688 Fax 727-815-8049
 
 
Home Índice Principal Unidades Portátiles  Kits para Recirulación Unidades Thru-Hull Kits para Conversión
Tanques Sistemas de Oxígeno Accesorios Instalación Guía Sobre Aireación Manual Técnico
Video Profesionales Lugares de Compra Concurso Reconocimientos Ligas
 

Sistemas de Oxígeno Puro

OXYGEN REGULATORS

Fish-FlO2

Designed for use in a marine environment.
Warning: Not for medical use.


KA901 Regulator

See more photos and technical information at: www.fish-flo2.com

Practice Catch & Release!

6 MONTH WARRANTY AGAINST DEFECTS & WORKMANSHIP,
PLUS

LIMITED-LIFETIME
REPLACEMENT WARRANTY

KA901 Regulator
Weight: 1.61 lbs
 
Suggested Retail $270.00

The FISH-FLO2 is the only known regulator specifically designed for use in a harsh marine environment! With technical assistance from  Mr. Gene Gilliland of the Oklahoma Fishery Research Lab and KeepAlive, Inc.,  and manufacturing expertise by American Healthcare Inc., the FISH-FLO2 Marine Regulator was born.

Mr. Gene Gilliland coauthored the booklet Keeping Bass Alive, with Professor Hal Schramm of Mississippi State University, and Mr. Bruce Shupp, B.A.S.S. National Conservation Director.

Nickel Plated Brass  with special internal components. Designed for use in a marine environment.

11 Settings: OFF, 1/32, 1/16, , 1/4, ½, ¾, 1, 2, 4, 6, and 8 liters per minute. These settings will allow various oxygen ratios with inexpensive air stones. The KA901 also provides sufficient pressure and oxygen for premium quality diffusers as our KA975 and KA9100 diffuser. At it's largest setting, the KA975 will consume 3/4 liters per minute.

Nut and Nipple style regulator body for use with CGA 540 Inlet Valve Cylinders.

Oxygen tank pressure gauge with gauge protector. Barbed Outlet for direct attachment of oxygen tubing.

Designed for use in a marine environment.
Warning: Not for medical use.

OXYGEN CYLINDERS


KA924 - KA915 - KA911

Warning: Not for medical use. Use industrial oxygen available from local welding shops


KA901 Regulator
KA975 Diffuser
KA911 Cylinder

CYLINDERS

KA911 Cylinder
KA915 Cylinder

KA924 Cylinder

KeepAlive Pure Oxygen Infusion Systems  use Chrome Plated Brass CGA 540 Inlet Cylinder Valves. Cylinders can be refilled from inexpensive commercial welding oxygen sources.

Cylinders have a white coat of baked on bonded powder paint.

1/16 LPM FLOW RATE:
KA911 approximately 68 hours.
KA915 approximately 113 hours.
KA924 approximately 181 hours.

CYLINDER DIMENSIONS (Not including valve)
KA915 11" Tall, 4.38" Diameter, 255 liters.
KA915 15" Tall, 4.38" Diameter, 425 liters.
KA924 24" Tall, 4.38" Diameter, 680 liters.

RECOMMENDED PROCEDURE FOR VALVING OXYGEN CYLINDERS

 

Part

No.

Service

Pressure

Diameter

Length

Empty

Weight

Oxygen

Water

Thread

Size 

 

(psi / bar)

(in / mm)

(in / mm)

(lbs / kgs)

(cu ft / liters)

(lbs / liters)

 

KA924

2015 / 139

4.38 / 111.3

24.9 / 632

7.4 / 3.4

24.0 / 680

10.2 / 4.6

.750-16UNF-2B

KA915

2015 / 139

4.38 / 111.3

16.5 / 419

5.1 / 2.3

15.0 / 425

6.4 / 2.9

.750-16UNF-2B

KA911

2015 / 139

4.38 / 111.3

10.7 / 272

3.6 / 1.6

9.0 / 255

3.8 / 1.7

.750-16UNF-2B

DIFFUSER DELIVERY SYSTEM

One of the simplest ways to dissolve oxygen in water is to introduce the oxygen as small bubbles. The smaller the bubbles the more efficient the absorption of oxygen.


KA975 Diffuser

The KA975 microbubble oxygen diffuser produces a cloud of extremely fine bubbles - 100 to 500 microns. This is much finer than graphite or carborundum diffusers, or porous hose, and because the diffuser is flat, the bubbles do not coalesce as with circular section diffusers.

The KA975 diffuser uses an ultra fine pore ceramic plate which ensures uniform bubbles across its entire surface. The ceramic is a clean and inert material.

The KA975 diffuser requires a regulator with a minimum of 25-35 lbs of output pressure.

KA975 Diffuser For most applications
KA9100 Diffuser

KeepAlive Diffusers  are the finest quality in the industry, and are manufactured for KeepAlive by Point Four. A quality diffuser is extremely important. Any lesser quality diffuser will produce larger bubbles and consume more oxygen.

Features and Benefits

  • The KA975 and KA9100 are the most efficient diffusers on the market. They use less gas and requires fewer diffusers to achieve the same results.

  • Robust construction. The ceramic plate is set in a rigid enamel coated aluminum frame and will not break if frozen.

  • Easy to install and simple to operate. It requires no power or complex attachment procedures.

  • Warranty - 2 years covering defective materials and workmanship.

Bubbling pressure

25 to 35 psi. (1.7 to 2.4 bar)

Absorption efficiency

Largely depends on submerged depth (or operating pressure), typically 40% to 50% at 1m depth; can be as high as 80% or even 100% at depths of 6m or more (also depends on flow rate).
Model KA975 KA9100
Diffusing area 6" x 1 1/8"
(15cm x 3cm)
12 1/8" x 1 1/8"
(31cm x 3cm)
Overall size 8 1/2" x 1 3/4"
(22cm x 4.5cm)
14 1/2" x 1 3/4"
(37cm x 4.5cm)
Weight 0.6lbs
(310g)
1.2lbs
(535g)
Recommended
operating range
up to 0.75 LPM
(1.6 SCFH)
up to 1.55 LPM
(3.2 SCFH)
Maximum flow rate
 @ 50 psi (3.5 bar)
2.2 LPM
(4.7 SCFH)
4.5 LPM
(9.5 SCFH)
Gas inlet connection 3/16" Hose Barb. 1/4" Hose Barb.

A DIFFUSER IS YOUR DELIVERY SYSTEM. DON'T SKIMP. BUY THE BEST!

FLEXIBLE TRANS-FILLS

Trans-fills with safety features cannot be stressed enough.
Keep
SAFETY  first when filling your own cylinders!
KeepAlive Transfills are the SAFEST trans-fills available for anglers.

NOT RECOMMENDED

A rigid trans-fill has inherent deficiencies and should not be used!

  • Filling a cylinder with a rigid trans-fill can be hazardous! Stress due to the weight of a cylinder on the trans-fill and associated connections may separate and result in serious injuries.

  • Most rigid trans-fills do not have a slow filling orifice, Cylinders can overheat to dangerous levels and cylinders may be damaged.

KA950 FLEXIBLE TRANS-FILL

TRANSFILL SAFETY INSTRUCTIONS

KA950 FLEXIBLE TRANS-FILL

Safety Features  

  • Flexible high pressure hose. Cylinder can be  placed on a solid surface while filling.

  • A slow filling orifice to prevent overheating of cylinders and hazardous conditions.

  • Single gauge will monitor filling cylinder pressure with filling cylinder valve open.

  • Single gauge will monitor supply cylinder pressure with filling cylinder valve closed.

  • Bleed valve to remove 2000 lbs of pressure from trans-fill before loosening and removing connections.

SAFETY FIRST AND ALWAYS!


Compre su
KeepAlive Infusor de Oxígeno
en Internet o en su Tienda
Favorita de Equipo de Pesca!

E-MAIL
Contáctenos! Haganos saber lo que piensa de sobre nuestros productos
y cualquier otra información que le gustaría compartir sobre mantener
carnada y capturas de pesca vivas. Si tiene algún problema en comprar un

KeepAlive
Infusor de Oxígeno, cuentenos sobre ello.
o

KeepAlive,,, Inc.
P.O. Box 1952
Tarpon Springs FL. 34688
TEL. (727) 841-0407
FAX (727) 815-8049

 

KeepAlive Aireadores y Viveros
mantendrá a sus peces vivos y saludables!